TMP TECHNICAL DATA VALUE 50 50 50 50 151 151 151C 361 361 361C 361C 1000C 1000C 1000C
High Vacuum Port nom.diam. 40 KF 40 CF 63 ISO-K 63 CF 63 ISO-K 100 CF 100 ISO-K 100 ISO-K 100 ISO-K 100 CF 160 ISO-K 160 CF 100 ISO-K 160 ISO-K 160 ISO-K 160 CF 6" ANSI 200 CF 250 ISO-K
Pumping Speed for N2 1/sec 33 33 55 55 115 145 145 345 400 345 400 850 1100 1150
Ultimate Pressure mbar 8 x 10-9 < 10-9 8 x 10-9 < 10-9 < 10-10 < 10-10 < 10-10 < 10-10 < 10-10 < 10-10 < 10-10 < 10-10 < 10-10 < 10-10
Forevacuum Pressure mbar 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 10-3-10-2 10-3-10-2 10-3-10--2
Recommended Forevacuum pump Trivac D2.5E D2.5E D2.5E D2.5E D4B D4B D16B D16B D16B D16B D25B D40B D40B D40B
Recommended Frequency Converter NT 10/12/13 10/12/13 10/12/13 20 20 20 20 20 20 20 20 20 20 20
Speed rpm 72 000 72 000 72 000 72 000 50 000 50 000 50 000 45 000 45 000 45 000 45 000 36 000 36 000 36 000
Coolant Flow Rate at 15 degrees Celcius 1/hr 20 20 20 20 20 20 20 20 20 20 20 20 20 20
Forevacuum Port nom. diam. 16 KF 16 KF 16 KF 16 KF 25 KF 25 KF 25 KF 25 KF 25 KF 25 KF 25 KF 40 KF/63 ISO-K 40 KF 40 KF/63 ISO-K
Vent Port nom. diam. - 10 KF - 10 KF - 10 KF 10 KF 10 KF 10 KF 10 KF 10 KF 10 KF3) 10 KF3) 10 KF3)
Weight kg 2 2 2 2 8 8 8 12 12 12 12 55 55 55
Maximum Ambient Temperature at Operation Celcius - 80 - 80 55 55 55 55 55 55 55 55 55 55